Modern Reliability Solutions

Our Mission

To continuously transform electrical reliability service expectations and capabilities within the industrial sector by educating our customers, incorporating state-of-the-art technology, utilizing advanced analysis methodologies, implementing timely reporting procedures, and applying robust preventative maintenance practices.

Power Transformers

  • DIELECTRIC FREQUENCY RESPONSE ANALYSIS

  • SWEEP FREQUENCY RESPONSE ANALYSIS

  • INSULATION RESISTANCE

  • POWER FACTOR AND DISSIPATION FACTOR

  • CAPACITANCE

  • TURNS RATIO

  • WINDING RESISTANCE

  • EXCITATION CURRENT

  • LEAKAGE REACTANCE

  • FREQUENCY RESPONSE OF STRAY LOSSES

  • MAGNETIC BALANCE

  • BUSHING ASSESSMENT

  • DEMAGNETIZATION

  • OIL QUALITY AND DISSOLVED GAS ANALYSIS

  • AUXILIARY EQUIPMENT

  • TRANSPORTATION INTEGRITY ASSESSMENT

  • INSULATION RESISTANCE

  • WINDING RESISTANCE

  • BURDEN

  • RATIO

  • EXCITATION

  • SATURATION

  • POLARITY

  • KNEE POINT

  • DEMAGNETIZATION

  • OVERPOTENTIAL/WITHSTAND

Circuit Breakers

  • FIRST TRIP ANALYSIS

  • VACUUM BOTTLE INTEGRITY

  • MAGNETRON ATMOSPHERIC CONDITION

  • PRIMARY AND SECONDARY INJECTION

  • TIMING VERIFICATION

  • TRIP/CLOSE COIL VERIFICATION

  • CONTACT/CONNECTION RESISTANCE

  • RUN-IN TESTING

  • STATION VOLTAGE

  • OVERPOTENTIAL/WITHSTAND

  • THERMAL MONITORING

Instrument Transformers

Motors & Generators

  • SWEEP FREQUENCY RESPONSE ANALYSIS

  • POWER FACTOR AND DISSIPATION FACTOR

  • INSULATION RESISTANCE

  • POLARIZATION INDEX

  • DIELECTRIC ABSORPTION RATIO

  • WINDING RESISTANCE

  • PRE-ENERGIZATION ROTATION VERIFICATION

What We Do

  1. Acceptance Testing

    Quantitative assurance that new equipment installations meet design specifications and industry standards

  2. Commissioning

    Functional analysis of new or modified equipment to ensure it will operate as intended

  3. Maintenance Testing

    Online and offline condition monitoring and diagnostics to provide health and life cycle assessment of installed assets

  4. Risk Mitigation

    Preventative and predictive maintenance programs tailored to specific operational needs and expectations

  5. Technical Consultation

    Guidance on power system operation, isolation, and maintenance best practice procedures to minimize risks and maximize safety

Relay Protection

  • TRANSMISSION, DISTRIBUTION, TRANSFORMER,

  • GENERATOR, MOTOR, AND LV RELAY SYSTEMS

  • NERC PRC COMPLIANCE TESTING

  • FUNCTION AND COORDINATION VERIFICATION

  • CALIBRATION AND EVENT REPORT ANALYSIS

  • FIBER COMMUNICATION VALIDATION

Switchgear & MCCs

  • INSULATION RESISTANCE

  • CONTACT/CONNECTION RESISTANCE

  • CONTROL WIRING VERIFICATION

  • INSTRUMENT COMMISSIONING

  • OVERPOTENTIAL/WITHSTAND

Cables

  • VERY LOW FREQUENCY AC HIPOT

  • TAN DELTA

  • PARTIAL DISCHARGE

  • FAULT LOCATION AND OPTICAL TDR